WEBVTT Kind: captions Language: en 00:00:04.610 --> 00:00:10.309 The XRV-100 and XRV-124 represent an important breakthrough in film-free 00:00:10.309 --> 00:00:14.680 end-to-end testing of proton therapy and radiosurgery treatment systems. 00:00:14.680 --> 00:00:20.140 Using a novel 3D scintillator cone and CCD camera, this exciting new technology from 00:00:20.140 --> 00:00:23.560 Logos Systems can quickly capture radiation beams in real time, 00:00:23.560 --> 00:00:29.120 dramatically improving the speed and accuracy of your current end-to-end QA test procedure. 00:00:29.120 --> 00:00:33.949 Not only do these XRV systems measure field size, symmetry, penumbra, 00:00:33.949 --> 00:00:38.210 output, timing and divergence in less than a second, they can also determine 00:00:38.210 --> 00:00:43.320 within several tenths of a millimeter the 3D location and direction of the beam. 00:00:43.320 --> 00:00:46.245 In the following animation, look for the green spots, 00:00:46.245 --> 00:00:50.981 where the x-ray or proton beam enters and exits the yellow scintillator cone. 00:00:50.981 --> 00:00:54.920 The green spots represent the visible light captured by the camera 00:00:54.920 --> 00:00:59.820 and used to calculate the beam profile, position, direction and timing data. 00:00:59.820 --> 00:01:05.140 Note how each different beam shot produces a unique set of entry and exit locations 00:01:05.140 --> 00:01:08.400 that can be used to reconstruct the beam path. 00:01:08.400 --> 00:01:13.180 The XRV-100 and 124 have embedded BB fiducials 00:01:13.180 --> 00:01:16.420 for alignment of the phantom within the treatment reference frame. 00:01:16.420 --> 00:01:20.620 Using a CT scan of the XRV phantom, precise positioning of the 00:01:20.620 --> 00:01:25.660 QA dose ISO Center can be accomplished using the treatment planning system. 00:01:25.663 --> 00:01:31.160 In the following recording of a real-time treatment, the x-ray imaging system used for patient 00:01:31.160 --> 00:01:35.690 targeting is illuminating the fiducials in order to provide guidance for precise 00:01:35.690 --> 00:01:40.700 positioning of the radiation beam within the volume of the phantom imaging cone. 00:01:40.700 --> 00:01:47.840 The XRV records both the x-ray flashes and the entry exit spots of the radiation beams. 00:01:47.840 --> 00:01:52.060 Once the QA treatment plan is captured by the XRV phantom, the 00:01:52.070 --> 00:01:57.140 Logos Systems BeamWorks and Volume Works software applications can be used to 00:01:57.140 --> 00:02:01.720 analyze the beam by beam targeting accuracy of the treatment delivery. 00:02:01.720 --> 00:02:06.380 Proton beam positions corrected for gantry wobble can be quickly verified in 00:02:06.380 --> 00:02:08.653 an all-electronic star shot test. 00:02:08.653 --> 00:02:11.959 For more information on the XRV-100 and XRV-124, 00:02:11.960 --> 00:02:17.840 please call Logos Systems at 831-600-6101 00:02:17.840 --> 00:02:24.340 or visit www.LogosVisionSystem.com.